Pathog Immun ; 5(1): 133-142, 2020.
Article in English | MEDLINE | ID: covidwho-2253465

ABSTRACT

BACKGROUND: Contaminated surfaces are a potential source for spread of respiratory viruses including SARS-CoV-2. Ultraviolet-C (UV-C) light is effective against RNA and DNA viruses and could be useful for decontamination of high-touch fomites that are shared by multiple users. METHODS: A modification of the American Society for Testing and Materials standard quantitative carrier disk test method (ASTM E-2197-11) was used to examine the effectiveness of UV-C light for rapid decontamination of plastic airport security bins inoculated at 3 sites with methicillin-resistant Staphylococcus aureus (MRSA) and bacteriophages MS2, PhiX174, and Phi6, an enveloped RNA virus used as a surrogate for coronaviruses. Reductions of 3 log10 on inoculated plastic bins were considered effective for decontamination. RESULTS: UV-C light administered as 10-, 20-, or 30-second cycles in proximity to a plastic bin reduced contamination on each of the test sites, including vertical and horizontal surfaces. The 30-second cycle met criteria for decontamination of all 3 test sites for all the test organisms except bacteriophage MS2 which was reduced by greater than 2 log10 PFU at each site. CONCLUSIONS: UV-C light is an attractive technology for rapid decontamination of airport security bins. Further work is needed to evaluate the utility of UV-C light in real-world settings and to develop methods to provide automated movement of bins through a UV-C decontamination process.

3.
Infect Control Hosp Epidemiol ; 43(6): 764-769, 2022 06.
Article in English | MEDLINE | ID: covidwho-1890039

ABSTRACT

OBJECTIVE: To assess the potential for contamination of personnel, patients, and the environment during use of contaminated N95 respirators and to compare the effectiveness of interventions to reduce contamination. DESIGN: Simulation study of patient care interactions using N95 respirators contaminated with a higher and lower inocula of the benign virus bacteriophage MS2. METHODS: In total, 12 healthcare personnel performed 3 standardized examinations of mannequins including (1) control with suboptimal respirator handling technique, (2) improved technique with glove change after each N95 contact, and (3) control with 1-minute ultraviolet-C light (UV-C) treatment prior to donning. The order of the examinations was randomized within each subject. The frequencies of contamination were compared among groups. Observations and simulations with fluorescent lotion were used to assess routes of transfer leading to contamination. RESULTS: With suboptimal respirator handling technique, bacteriophage MS2 was frequently transferred to the participants, mannequin, and environmental surfaces and fomites. Improved technique resulted in significantly reduced transfer of MS2 in the higher inoculum simulations (P < .01), whereas UV-C treatment reduced transfer in both the higher- and lower-inoculum simulations (P < .01). Observations and simulations with fluorescent lotion demonstrated multiple potential routes of transfer to participants, mannequin, and surfaces, including both direct contact with the contaminated respirator and indirect contact via contaminated gloves. CONCLUSION: Reuse of contaminated N95 respirators can result in contamination of personnel and the environment even when correct technique is used. Decontamination technologies, such as UV-C, could reduce the risk for transmission.


Subject(s)
COVID-19 , N95 Respirators , Decontamination/methods , Equipment Reuse , Fomites , Humans , Levivirus , SARS-CoV-2
5.
Pathog Immun ; 6(1): 104-115, 2021.
Article in English | MEDLINE | ID: covidwho-1271085

ABSTRACT

BACKGROUND: Ultraviolet-C (UV-C) light devices are effective in reducing contamination on N95 filtering facepiece respirators. However, limited information is available on whether UV-C devices meet the Food and Drug Administration's (FDA) microbiological requirements for Emergency Use Authorization (EUA) for respirator bioburden reduction. METHODS: We tested the ability of 2 UV-C light boxes to achieve the 3-log10 microorganism reductions required for EUA for reuse by single users. Whole 3M 1860 or Moldex 1513 respirators were inoculated on the exterior facepiece, interior facepiece, and internal fibers with bacteriophage MS2 and/or 4 strains of bacteria and treated with UV-C cycles of 1 or 20 minutes. Colorimetric indicators were used to assess penetration of UV-C through the respirators. RESULTS: For 1 UV-C box, a 20-minute treatment achieved the required bioburden reduction for Moldex 1513 but not 3M 1860 respirators. For the second UV-C box, a 1-minute treatment achieved the required bioburden reduction in 4 bacterial strains for the Moldex 1513 respirator. Colorimetric indicators demonstrated penetration of UV-C through all layers of the Moldex 1513 respirator but not the 3M 1860 respirator. CONCLUSIONS: Our findings demonstrate that UV-C box technologies can achieve bioburden reductions required by the FDA for EUA for single users but highlight the potential for variable efficacy for different types of respirators.

6.
Infect Control Hosp Epidemiol ; 42(2): 215-217, 2021 02.
Article in English | MEDLINE | ID: covidwho-1083571

ABSTRACT

On coronavirus disease 2019 (COVID-19) wards, severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) nucleic acid was frequently detected on high-touch surfaces, floors, and socks inside patient rooms. Contamination of floors and shoes was common outside patient rooms on the COVID-19 wards but decreased after improvements in floor cleaning and disinfection were implemented.


Subject(s)
COVID-19/transmission , Environmental Pollution/analysis , Intensive Care Units , Patients' Rooms , SARS-CoV-2/isolation & purification , COVID-19/virology , Clothing , Disinfection/methods , Equipment Contamination , Hospitals, Veterans , Humans , Ohio , Real-Time Polymerase Chain Reaction
7.
Infect Control Hosp Epidemiol ; 42(6): 678-687, 2021 06.
Article in English | MEDLINE | ID: covidwho-932192

ABSTRACT

BACKGROUND: Critical shortages of personal protective equipment, especially N95 respirators, during the coronavirus disease 2019 (COVID-19) pandemic continues to be a source of concern. Novel methods of N95 filtering face-piece respirator decontamination that can be scaled-up for in-hospital use can help address this concern and keep healthcare workers (HCWs) safe. METHODS: A multidisciplinary pragmatic study was conducted to evaluate the use of an ultrasonic room high-level disinfection system (HLDS) that generates aerosolized peracetic acid (PAA) and hydrogen peroxide for decontamination of large numbers of N95 respirators. A cycle duration that consistently achieved disinfection of N95 respirators (defined as ≥6 log10 reductions in bacteriophage MS2 and Geobacillus stearothermophilus spores inoculated onto respirators) was identified. The treated masks were assessed for changes to their hydrophobicity, material structure, strap elasticity, and filtration efficiency. PAA and hydrogen peroxide off-gassing from treated masks were also assessed. RESULTS: The PAA room HLDS was effective for disinfection of bacteriophage MS2 and G. stearothermophilus spores on respirators in a 2,447 cubic-foot (69.6 cubic-meter) room with an aerosol deployment time of 16 minutes and a dwell time of 32 minutes. The total cycle time was 1 hour and 16 minutes. After 5 treatment cycles, no adverse effects were detected on filtration efficiency, structural integrity, or strap elasticity. There was no detectable off-gassing of PAA and hydrogen peroxide from the treated masks at 20 and 60 minutes after the disinfection cycle, respectively. CONCLUSION: The PAA room disinfection system provides a rapidly scalable solution for in-hospital decontamination of large numbers of N95 respirators during the COVID-19 pandemic.


Subject(s)
COVID-19/prevention & control , Decontamination/methods , Disinfectants/therapeutic use , Equipment Contamination/prevention & control , N95 Respirators/virology , Peracetic Acid/therapeutic use , SARS-CoV-2 , Aerosols , Cross Infection/prevention & control , Cross Infection/virology , Disinfectants/administration & dosage , Geobacillus stearothermophilus , Humans , Hydrogen Peroxide/administration & dosage , Hydrogen Peroxide/therapeutic use , Levivirus , N95 Respirators/adverse effects , N95 Respirators/microbiology , Peracetic Acid/administration & dosage
8.
Am J Infect Control ; 49(4): 424-429, 2021 04.
Article in English | MEDLINE | ID: covidwho-917197

ABSTRACT

BACKGROUND: Filtering facepiece respirators (FFR) are critical for protecting essential personnel and limiting the spread of disease. Due to the current COVID-19 pandemic, FFR supplies are dwindling in many health systems, necessitating re-use of potentially contaminated FFR. Multiple decontamination solutions have been developed to meet this pressing need, including systems designed for bulk decontamination of FFR using vaporous hydrogen peroxide or ultraviolet-C (UV-C) radiation. However, the large scale on which these devices operate may not be logistically practical for small or rural health care settings or for ad hoc use at points-of-care. METHODS: Here, we present the Synchronous UV Decontamination System, a novel device for rapidly deployable, point-of-care decontamination using UV-C germicidal irradiation. We designed a compact, easy-to-use device capable of delivering over 2 J cm2 of UV-C radiation in one minute. RESULTS: We experimentally tested Synchronous UV Decontamination System' microbicidal capacity and found that it eliminates near all virus from the surface of tested FFRs, with less efficacy against pathogens embedded in the inner layers of the masks. CONCLUSIONS: This short decontamination time should enable care-providers to incorporate decontamination of FFR into a normal donning and doffing routine following patient encounters.


Subject(s)
COVID-19/prevention & control , Decontamination/instrumentation , Point-of-Care Systems , Respiratory Protective Devices/virology , SARS-CoV-2 , Ultraviolet Rays , COVID-19/virology , Decontamination/methods , Equipment Reuse , Humans
9.
Am J Infect Control ; 48(8): 951-954, 2020 08.
Article in English | MEDLINE | ID: covidwho-549206

ABSTRACT

In the setting of the coronavirus disease 2019 pandemic, efficient methods are needed to decontaminate shared portable devices and large open areas such as waiting rooms. We found that wheelchairs, portable equipment, and waiting room chairs were frequently contaminated with potential pathogens. After minimal manual precleaning of areas with visible soiling, application of a dilute sodium hypochlorite disinfectant using an electrostatic sprayer provided rapid and effective decontamination and eliminated the benign virus bacteriophage MS2 from inoculated surfaces.


Subject(s)
Coronavirus Infections/prevention & control , Cross Infection/prevention & control , Decontamination/methods , Disinfection/methods , Equipment Contamination/prevention & control , Pandemics/prevention & control , Pneumonia, Viral/prevention & control , Betacoronavirus/pathogenicity , COVID-19 , Cross Infection/virology , Disinfectants/administration & dosage , Humans , SARS-CoV-2
10.
Pathog Immun ; 5(1): 52-67, 2020.
Article in English | MEDLINE | ID: covidwho-177364

ABSTRACT

BACKGROUND: Shortages of personal protective equipment (PPE) including N95 respirators are an urgent concern in the setting of the global COVID-19 pandemic. Decontamination of PPE could be useful to maintain adequate supplies, but there is uncertainty regarding the efficacy of decontamination technologies. METHODS: A modification of the American Society for Testing and Materials standard quantitative carrier disk test method (ASTM E-2197-11) was used to examine the effectiveness of 3 methods, including ultraviolet-C (UV-C) light, a high-level disinfection cabinet that generates aerosolized peracetic acid and hydrogen peroxide, and dry heat at 70°C for 30 minutes. We assessed the decontamination of 3 commercial N95 respirators inoculated with methicillin-resistant Staphylococcus aureus (MRSA) and bacteriophages MS2 and Phi6; the latter is an enveloped RNA virus used as a surrogate for coronaviruses. Three and 6 log10 reductions on respirators were considered effective for decontamination and disinfection, respectively. RESULTS: UV-C administered as a 1-minute cycle in a UV-C box or a 30-minute cycle by a room decontamination device reduced contamination but did not meet criteria for decontamination of the viruses from all sites on the N95s. The high-level disinfection cabinet was effective for decontamination of the N95s and achieved disinfection with an extended 31-minute cycle. Dry heat at 70°C for 30 minutes was not effective for decontamination of the bacteriophages. CONCLUSIONS: UV-C could be useful to reduce contamination on N95 respirators. However, the UV-C technologies studied did not meet pre-established criteria for decontamination under the test conditions used. The high-level disinfection cabinet was more effective and met criteria for disinfection with an extended cycle.